Skip to Content

PC8500 Portable pH/Conductivity Meter Kit with GLP Data Logger and USB Data Output

Cat. No.
PC8500
https://www.scilogex.com/web/image/product.template/1045/image_1920?unique=436519c

590.00 590.0 USD 590.00 In stock

590.00

Currently Out-of-Stock

This combination does not exist.

         

For more information please call +1 (860) 436-9221 or email us at info@scilogex.com

Product Description

Apera Instruments Premium Series PC8500 Portable pH/Conductivity Meter Kit is designed for lab-grade pH and conductivity measurement in the field with a variety of intelligent functions and features in a rugged structure. Up to three electrodes can be connected to the meter simultaneously for the measurement of multiple parameters, including pH, conductivity, TDS, salinity, ORP, and temp.

ORP measurement is available in mV mode with an ORP probe connected (model 301Pt-C, sold separately).

Easy Calibration
Quick and easy 1- to 3-point auto. calibration, recognizing pH standards of 1.68, 4.00, 7.00, 10. 01, and 12.45; conductivity standards of 1413 µS, 12.88 mS, 84 µS, and 111.8 mS.

The slope data will be displayed after completing 2nd and 3rd point calibration, indicating the condition of your pH electrode. The self-diagnosis function ensures calibration will be properly performed.

Complete Parameter Settings
Auto. lock, auto. power off function, and calibration date check available. Calibration reminder can be set up.

pH standard series, pH resolution, stability criteria, temperature unit, conductivity cell constant, reference temperature, and temperature compensation coefficient are all customizable. TDS conversion factor can be set from 0.40 to 1.00.


Product Specifications

Technical Specifications

pH Measuring Range (-2.00 to 19.99)pH
Resolution 0.1/0.01 pH
Accuracy ±0.01 pH ±1 digit
Temperature (0 to 100)˚C (Auto. or Manual)
Compensation range
Calibration Point 1 to 3 points
mV Measuring Range ±2000mV
Resolution 1mV
Accuracy ±0.1% FS ±1 digit
Cond. Measuring Range Conductivity:0~200 mS/cm, divided into five ranges, automatically switch measuring range. (0 to 19.99) μS/cm; (20.0 to 199.9) μS/cm; (200 to 1999) μS/cm; (2.00 to 19.99) mS/cm; (20.0 to 199.9) mS/cm TDS: (0 to 100) g/L; Salinity: (0 to 100) ppt
Resolution 0.01/0.1/1μS/cm 0.01/0.1 mS/cm
Accuracy ±1.0% FS ±1 digit
Temperature (0 to 50)˚C (Auto. or Manual)
Compensation range
Cell constant 0.1/1/10 cm-1
Temp. Measuring Range 0 to 100℃
Resolution 0.1℃
Accuracy ±0.5℃±1 digit


Other Specifications

Data Storage 1000 groups
Storage Content Numbering, measuring value and temperature value, data and time
Power 3* AA alkaline batteries
Dimension & Weight Meter: (88*170*33)mm / 313g Case: (360*270*76)mm / 1.6kg
Connector BNC for pH and ORP; RCA for temperature, 8-pin for conductivity
What's in the box? PC8500 meter, 201T-F pH/temp. electrode, 2301T-S conductivity/temp. electrode, electrode clip, software flash drive, USB cable, 50ml of pH buffers (4.00, 7.00), 50ml of conductivity standards (1413µS, 12.88mS), screwdriver (for battery replacement), instruction manual, carrying case



Data logger with USB Output

Auto. or manual data logging with GLP Data management (500 sets of data storage) and USB data output for further analysis and report (only for Windows-based PCs).

Large backlit LCD display

1.Stability icon. Take the reading when the smiley face stays on screen.
2.Icons for finished calibrations
3.Simultaneous temperature display
4.Time
5.Data storage

Suitable for lab-use as well

The foldable stand allows usage as a benchtop meter.

Build tough

The IP57 water-resistant structure makes the meter ideal for use in harsh environment. The rubber sleeve protects the instrument from general impact and gives you a firm grip.

2301T-S Conductivity Electrode

The equipped Apera 2301T-S Conductivity Electrode is built with a proprietary firm platinum black cell, which ensures high accuracy (±1% F.S) in an ultra-wide range (0 to 200 mS/cm or 200,000 µS/cm). The built-in temp. sensor enables ATC of the meter and the PVC body make it resistant to corrosions.

Proprietary electrode structure

A unique junction composed of ceramic and fiber filaments efficiently reduces junction clogging. The built-in temperature sensor tests pH and temperature simultaneously, enabling auto. temp compensation (ATC).

pH Sensor ShieldData logger with USB Output

The detachable sensor shield protects the sensitive glass membrane from accidental damage.

Compatibility with LabSen pH Electrodes

Standard BNC connector, compatible with Apera LabSen Series pH electrodes for specialized applications.


Product Accessories

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
View our 2025 Product Catalog

Get our complete and latest product portfolio for free.

View Scilogex Catalog Now

Earn Rewards

Enjoy exclusive deals & discounts on our lab equipment & supplies.

Start Earning Points​​​

Download Scilogex Literature

Find a collection of product manuals and brochure PDFs available for download.

Browse Here